Abstrait

Hybrid Endovascular Repair in Aortic Arch Pathologies

Wei Guo

Hybrid repair is increasingly evolving as an alternative option for selected patients, and promising initial results have been reported. The aim of this study was to introduce our experiences and evaluate mid-term results of supra aortic transpositions for extended endovascular repair of aortic arch pathologies. From December 2002 to January 2008, 25 patients with thoracic aortic aneurysms and dissections involving the aortic arch were treated with hybrid endovascular treatment in our center. Of the 25 cases, 14 were atherosclerotic thoracic aortic aneurysms and 11 were thoracic aortic dissection. The hybrid repair method included total-arch transpositions (15 cases) or hemi-arch transpositions (10 cases), and endovascular procedures. All hybrid endovascular procedures were completed successfully. Three early residual type-I endo leaks and one type-II endo leak were observed. Stroke occurred in three patients (8%) during the in-hospital stage. The perioperative mortality rate was 4%; one patients died post-operatively from catheter related complications. In conclusion, the results are encouraging for endovascular aortic arch repair in combination with supra-aortic transposition in high risk cases. Aortic endografting offers good mid-term results. Mid-term results of the hybrid approach in elderly patients with aortic arch pathologies are satisfying.

Avertissement: Ce résumé a été traduit à l'aide d'outils d'intelligence artificielle et n'a pas encore été examiné ni vérifié